101-102, Sector 15, Korangi Industrial Area, Karachi
Ex-Certified Equipment Specialist
Art. No: 325356 Series: 6602A IECEx (IBE), ATEX, PESO, CE, ISO 9001

Linear luminaire, 5700 K – cool white; 5594lm; 44 W, 220 … 240 V, Drilled holes: 4 x M20, Size: 4, Zone 2/21/22

Product Type: 6602/1243-0100-152-2222-22-857
Lamp Wattage 44 W
Luminous Flux 5,594 lm
System Efficacy 127 lm/W
Light Colour 5700 K – Cool White
Voltage AC/DC 220 … 240 V AC
Enclosure & Holes Size 4 (Length: ~1310 mm)
Key Features | Technical Specs | Certifications | Downloads | FAQs
Engineering Excellence

Key Features & Operational Benefits

Engineered to the highest IEC 60079 international standards to ensure continuous safety and performance in hazardous plant environments.

Key Features

  • Smart Central Locking System: Effortless single-key access for quick maintenance.
  • 2kV Surge Protection: Shields the luminaire driver against high-voltage spikes.
  • Superior Energy Efficiency: Delivers 127-130 lumens/watt for peak efficiency.
  • Long-Lasting Performance: Exceeds 60,000h service life at +55°C ambient.
  • Diffused Optics: 120°x120° beam distribution eliminates glare.
  • Pole & Surface Mounting: Compatible with mounting sleeves and ceiling brackets.

Operational Benefits

  • Extended Maintenance Lifespan: Drastically reduces plant downtime and replacement cycles.
  • Total Explosion Risk Elimination: Guaranteed containment of internal sparks in Gas and Dust zones.
  • Energy & Operating Cost Reduction: High-efficiency architecture delivers maximum output with lower power draw.
  • Turnkey Retrofit Compatibility: Easy mounting geometry allows direct replacement of legacy systems.
  • Full Local Engineering Support: Backed by Maple Pakistan nationwide engineering inventory and FAT documentation.
Data Sheet Matrix

Technical Data Specifications

Download Full Specification PDF
Article Number (Art. No.) 325356
Product Type Designation Code 6602/1243-0100-152-2222-22-857
Maple Product Series 6602A (EXLUX 6602 Series)
Application Range (Hazardous Zones) Zone 2, 21, 22
Gas Explosion Protection Marking II 3 G Ex nR IIC T6 Gc
Dust Explosion Protection Marking II 2 D Ex tb IIIC T85°C Db
Ingress Protection (IP Rating) IP66 / IP67 (EN/IEC 60529)
Mechanical Impact Withstand (IK) IK10 (IEC 62262)
Temperature Class & Gas Groups T6 / Gas Group IIC
Rated Power Consumption 44 W
Luminous Flux Output 5,594 lm
System Luminous Efficacy 127 lm/W
Correlated Colour Temperature (CCT) 5700 K – Cool White
Colour Rendering Index (CRI) ≥ 80
Beam Distribution Pattern 120° x 120° Diffused Optics
Rated Operational Voltage AC 220 … 240 V AC
Rated Operational Voltage DC 194 … 250 V DC
Rated Frequency Range 50 – 60 Hz
Enclosure Construction Material Glass-fibre reinforced polyester (GRP)
Diffuser / Cover Material Impact-resistant Polycarbonate
Enclosure Size & Drilled Cable Entries Size 4 (Length: ~1310 mm) (4 x M20 threaded drilled holes)
Ambient Operating Temperature Range -30 °C to +55 °C
Service Life (LED Driver / Luminaire) L90B50 ≥ 100,000 h at Ta ≤ +55°C
Surge Protection Level Integrated surge suppression up to 2 kV
International Conformity & Certificates IECEx (IBE), ATEX, PESO, CE, ISO 9001 (IECEx IBE 24.0030 / IECEXIBE240030X)
Global Compliance

Certifications & International Standards

Maple Pakistan equipment adheres strictly to international explosion protection safety mandates and laboratory testing regimes.

ATEX Directive 2014/34/EU

Certified equipment category 2G / 2D for safe deployment across explosive gas, vapor, mist, and combustible dust environments.

IECEx System Certification

Internationally accepted conformity certificate guaranteeing product uniformity and safe global oil, gas, and energy plant operations.

IEC 60079 Standards

Full adherence to IEC 60079-0, IEC 60079-1 (Ex d), IEC 60079-7 (Ex e), and IEC 60079-31 (Ex tb) construction parameters.

IP66 / IP67 (EN/IEC 60529)

Rigorous ingress protection against heavy water jets, torrential rain, dust storms, and saltwater coastal corrosion.

Documentation

Datasheets, Catalogues & Manuals

View All Downloads

Product Technical Datasheet

Comprehensive electrical parameters, explosion protection markings, dimensional drawings, and order keys.

Download Datasheet (PDF)

Product Series Brochure

Engineering overview, luminous polar curve distribution diagrams, and optional accessory catalog.

Download Brochure (PDF)

Operating & Maintenance Manual

Detailed mechanical mounting guide, cable gland torque specifications, and routine maintenance safety protocols.

Download Manual (PDF)

CAD Drawings & Dialux Files

Request 2D/3D STEP models, AutoCAD dimension blocks, and certified Dialux photometric files (.ldt / .ies).

Request CAD / Dialux
Critical Deployments

Engineered for High-Hazard Industries

Proven operational track record across critical energy, processing, and heavy industrial infrastructures.

Oil & Gas Refineries

Upstream drilling, crude refining distillation units, tank storage farms, and gas compression manifolds.

Petrochemical Facilities

Polymer synthesis, cracker furnaces, volatile solvent handling, and chemical synthesis reactors.

Marine & Offshore Rigs

Offshore production platforms, FPSO vessels, LNG carriers, and saltwater marine terminals.

Pharmaceutical Cleanrooms

Active pharmaceutical ingredient (API) extraction, powder granulating, and cleanroom production.

Fertilizer & Grain Silos

Combustible grain handling, bagging areas, fertilizer towers, and coal conveying.

Certified Portfolio

Related Explosion-Protected Equipment

View All in Luminaires & Lighting Systems
Technical Inquiries

Frequently Asked Questions

Technical compliance, hazardous classification, and procurement answers for industrial project engineers.

In which hazardous area zones can Linear luminaire, 5700 K – cool white; 5594lm; 44 W, 220 … 240 V, Drilled holes: 4 x M20, Size: 4, Zone 2/21/22 be deployed?
This equipment is certified for hazardous locations classified under Zone 2, 21, 22 according to IEC 60079 international standards. It provides proven explosion protection in areas where flammable gases (Gas Groups IIA, IIB, IIC) and combustible dusts (IIIA, IIIB, IIIC) may be present during normal or upset plant operations.
What documentation and test certificates are supplied with this unit?
Each unit is delivered with official third-party ATEX and IECEx conformity certificates, factory acceptance test (FAT) inspection reports, material test mill certificates, and comprehensive technical installation & maintenance manuals.
Can custom cable entries, terminals, or voltages be configured?
Yes. Maple Pakistan customizes cable entries (M20, M25, M32, NPT), armored/unarmored barrier glands, terminal configurations, mounting brackets, and specialized auxiliary contacts according to client project engineering drawings.
How can I receive quotation and delivery support in Pakistan?
Maple Pakistan maintains dedicated technical sales and engineering support offices across Karachi, Lahore, and Islamabad. You can request formal RFQ quotations directly online, via WhatsApp at +92 320 2619362, or by contacting our hazardous area application team.

Need Engineering Sizing or a Certified Quotation?

Our hazardous area certified engineers provide Dialux lighting calculations, terminal box custom design, and explosion-protection audits across Pakistan.

Request Project Quotation Chat with Engineers
Call WhatsApp Quote